| Sign In | Join Free | My xuijs.com |
|
Brand Name : suntree
Model Number : GCK
Certification : A2014CCC0301-1847502
Place of Origin : China
MOQ : 1
Price : 2000$
Payment Terms : T/T, D/P, D/A, L/C, Western Union, MoneyGram
Supply Ability : 1000pcs /month
Delivery Time : 20-30
Packaging Details : wooden bx
GCK type switchgear is suitable for three-phase AC 50 /60HZ, max voltage 660V, rated current to 3150A system and three-phase four-wire and three-phase five-wire,
Compared with the GCS cabinet, which has a maximum of 11 module small drawers and a minimum unit of 1/2, and the MNS cabinet, which has a maximum of 9 module small drawers and a minimum unit of 1/4,
This series of products with high breaking capacity, good dynamic stability, advanced and reasonable structure, electrical program of practical, series, strong versatility, various schemes of unit combination, a cabinet contained many circuits.
It accords with the standards IEC439 NEMA ICS2-322 as well as the GB7251-87 "Low voltage complete switch device " national standards and ZBK36001-89 "low voltage withdraw type complete switch device" professional standards"


Production code :

Technical specification
| Model | Item | Specification | ||
| GCK | Standard | IEC 439-1,GB7251-1 | ||
| IP grade | IP30 | |||
| Rated operational voltage(V) | AC 360,600 | |||
| Frequency(Hz) | 50/60 | |||
| Rated insulation voltage(V) | 660 | |||
| Operating conditions | Environment | Indoor | ||
| Control motor capacity(kW) | 0.45~155 | |||
| Mechanical life(times) | 500 | |||
| Rated current(A) | Horizontal bus | 1600,2000,2500,3150 | ||
| Vertical bus | 630,800 | |||
| Main circuit contact connector | 200,400,630 | |||
| Auxiliary circuit contact connector | 10,20 | |||
| Maximum current of feed circuit | PC cabinet | 1600 | ||
| MCC cabinet | 630 | |||
| Electric circuit | 1000,1600,2000,2500,3150 | |||
| Rated short-time withstand current(kA) | 30,50,80 | |||
| Rated peak withstand current(kA) | 63,105,176 | |||
| Withstand Voltage(V/min) | 2500 | |||
Sevice condictions :
| Normal service conditions of switchgear as follows: | |
| Ambient temperature: | |
| Maximum | +40°C |
| Maximum 24 hour average | +35°C |
| Minimum (according to minus 15 indoor classes) | -5°C |
| Ambient humidity: | |
| Daily average relative humidity | less than 95% |
| Monthly average relative humidity | less than 90% |
| Earthquake intensity | less than 8 degree |
| Height above sea level | less than 2000m |
This product should not be used under conditions of fire, explosion, earthquake and chemical corrosion environments.
Structure diagram:


|
|
GCK Withdrawable Entry And Exit Power Distribution Cabinet Low Voltage Images |